button.) 
 
 
 
Click  the  TEST 
button,  PULL  DOWN 
mode  into  10  seconds 
(or  open  door,  lock, 
press  the  "Fridge" 
button,  press  the  "My 
zone" button 5 times.) 
1) COMP high speed 
64Hz; 
2) F-FAN 12V; 
3) DEF-HTR OFF; 
4) Refrigerated door 
fully open; 
5) The variable 
temperature damper 
opens the angle for 
30°; 
6) Display panel 
displayT1。 
This function does not quit without 
manual withdrawal or power failure. 
Click  two  time  TEST 
button,  after  10 
seconds  into  the  pre 
cooling  forced  defrost 
function (or in the T1, 
press  the  "Lock" 
button, enter the T2) 
1) COMP OFF; 
2) F-FAN OFF; 
3) DEF-HTR ON; 
4)PC air switch off; 
5)my  zone  air  switch 
off; 
6)Panel display T2; 
7)  Cancel  the  defrost  in 
defrosting  process, 
immediately  quit 
defrost 
Start to frost: 
If D-SNR = 12 degree, D-HTR 10S exit; 
If  D-SNR  is  less  than  12  degree,  then 
D-HTR to D-SNR reached 12 degrees (the 
longest  90min  D-SNR  exit  forced  exit; 
D-SNR fault, the 30min exit) exit; 
Manual forced exit, exit 
Click  5  times  TEST 
button,  exit  TEST 
mode   
 
【3】  Exhibition function 
Entering mode: Open the door, locking condition, press the "Freezer" button and press 
"Lock" button 5 times to enter the exhibition function. 
Exit mode: The exhibition function, open the door, locking condition, press the "Freezer" 
button and press "Lock" button 5 times to exit the exhibition function. 
Control mode
:
The refrigerator enter into the exhibition function mode,PC, frozen lights, 
blue lights , compressor, fan, air switch, heating wire and other load stop working, the 
refrigerator display can work