7.1Codes and Description HSU-18HEA03/R2
7.1.1Problem Symptoms and Measures 
Symptom  Check Item  Details of Measure 
Reference
page
Check the power supply.
 
Check  to  make  sure  that  the  rated  voltage  is 
supplied. 
---- 
None  of  the 
units operates 
Check the indoor PCB 
Check  to  make  sure  that  the  indoor  PCB  is 
broken 
---- 
---- 
Equipment 
operates  but 
does not cool, 
or  does  not 
heat  (only  for 
heat pump) 
Diagnosis  by  service 
port  pressure  and 
operating current. 
Check for insufficient gas. 
---- 
Large 
operating 
noise  and 
vibrations 
Check  the  installation 
condition. 
Check  to  make  sure  that  the  required  spaces 
for installation (specified in the Technical Guide, 
etc.) are provided. 
---- 
 
 
 
7.1.2 Error Codes and Description indoor display
 
Code indication 
 
indoor 
Description 
Reference 
Page 
E1  Room temperature sensor failure    ---- 
E2  Heat-exchange sensor failure  ---- 
E4  Indoor EEPROM error  ---- 
Indoor Malfunction 
E14  Indoor fan motor malfunction  ---- 
The code indication that is listed above is the main fault 
 
Troubleshooting         
Caution
Be sure to turn off power switch before connect or disconnect connector,      or else parts damage may be   
occurred.
 
E1: Room temperature sensor failure          CN6 
E2: Heat-exchange sensor failure                CN6 
   
 
 
 
 
 
 
 
 
 
 
HSU-18,22HEA03/R2                                                Service Diagnosis