HSU-09(12)HA/HVA/RHA103/R2(DB) Capacity
50
Domestic air conditioner
outdoor temp.
(humidity 46%)
DB/WB 16℃
19
22℃
15
665 751 765
25
690 773 776
30
696 778 778
35
706 783 796
40
743 822 834
45
772 854 870
HSU-09RHA103/R2(DB)
performance curves
COOLING SUCTION PRESSURE
.talbe
in
door temp.
COOLING SUCTION PRESSURE
400
500
600
700
800
900
1000
15 25 30 35 40 45
Outdoor Temp
DI
SCHARGE P RESSURE
16
19
22
COOLING SUCTION PRESSURE
400
500
600
700
800
900
1000
15℃ 25℃ 30℃ 35℃ 40℃ 45℃
Outdoor Temp
DI
SCHARGE P RESSURE
16℃
19℃
22℃