EasyManua.ls Logo

Haier HSU-09/12HA103/R2(DB) - Electrical Specifications

Haier HSU-09/12HA103/R2(DB)
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL SPECIFICATIONS
OUTDOOR UNITS
NET DIMENSIONS
(stop valve, and bottom support
is not included)
WEIGHT
COLOR
SOUND LEVEL
FAN
PIPING CONNECTIONS
INSULATION MATERIAL
HSU-09HA103/R2(DB)
HSU-12HA103/R2(DB)
Unit
Unit
Sound power(cooling/heating)(6)
dB(A)
dB(A)
Air flow rate(cooling/heating)
high
low
m /min
3
m /min
3
Speed(cooling/heating)
high
low
Type
Motor output
W
liquid
gas
drain
rpm
rpm
H
W
D
mm
mm
mm
kg
Heat insulation type
540
780 780
245
540
245
34 40.5
Sound pressure(cooling/heating)(5)
high
high
31.6/31.6
19.7/19.7
31.6/31.6
19.7/19.7
800/800 800/800
500
500/500
/500
Propeller fan
19
19
6.35
6.35
9.52
9.52
18 18
both liquid and gas pipes
white
white
53.8/54.8
63/64
54.2/54.6
64/64
REFRIGERANT CIRCUIT
Refrigerant type
Refrigerant charge
Maximum allowable distance between
indoor and outdoo
Maximum allowable level difference
Refrigerant control
kg
m
m
COMPRESSOR
Type
Model
Motor output
Oil type
Oil charge volume
L
mm
mm
mm
Unit
R410a
R410a
0.65
0.94
20
2015
15
w
650
0.37
0.48
HSU-09(12)HA/RHA/HVA103/R2(DB) Specifications
4
Domestic air conditioner
Rotary Compressor
For combination indoor units+ outdoor units:
cooling ANominal
running
current
heating A
cooling AMaximum
running
current
heating A
cooling A
CURRENT
Starting
current
heating A
HSU-09HA103/R2(DB)
HSU-12HA103/R2(DB)
3.9
4.6
5.8
6.3
4.9
4.8
6.9
7.0
1.2
1.2
1.3
1.3
ELECTRICAL SPECIFICATIONS
capillary
DA89X1C-20FZ DA108X1C-20FZ3
ESTER OIL
VG74
ESTER OIL
VG74
855

Related product manuals