Air Conditioner
Edition:2006/01/09
Indoor unit
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person. The type of connecting wire is H05RN-F or H07RN-F.
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring
is not correct, proper operation can not be carried out and will cause defect.
3G1.5mm
2
3G2.0mm
2
3G2.5mm
2
Power cable: 3G1.5mm
2
Power cable: 3G2.5mm
2
Power cable: 3G2.5mm
2
HSU-22C13
Indoor unit
Outdoor unit
YEL/GRN
BLK
WHT
YEL/GRN
BLK
4
WHT
HSU-24C13
1(L) 2(N)
LN
POWER PLUG
{
L
N
G
HSU-18C13
Indoor unit
Outdoor unit
YEL/GRN
BLK
WHT
YEL/GRN
WHT
BLK
4
1(L) 2(N)
LN
POWER PLUG
{
L
N
G
HSU-09C13
HSU-12C13
Indoor unit
Outdoor unit
YEL/GRN
BLK
WHT
4
YEL/GRN
WHT
BLK
1(L) 2(N)
36