7.1.4.1 The ou tdoor fan control when refrigerating or dehumidifying
After the compressor is started for 5 seconds,
the outdoor fan
is
started according to the
temperature conditions of the outdoor environment.
The outdoor fan control when heating
7.1.4.2
Domestic air conditioner
21
<40 40∽60 ≥60
500 600 700
850 900 900
when cooling
compressor
frequency
( Hz)
Twh(℃)
900
≤23
29∽40
≥40
<60 60∽90 ≥90
800 900 900
700 800 850
≥16 700
when heaating
compressor
frequency
(Hz)
Twh(℃)
≤10
10-16
Functions and control
In 3 minutes,
After 3 minutes,The wind speed control is related to the frequency of the compressor and the temperature
conditions of the outdoor environment.
After the compressor is started for 5 seconds,
the outdoor fan
is
started according to the
temperature conditions of the outdoor environment.
In 3 minutes,
Twh(℃) Twh <10℃ 10℃< Twh <16℃ Twh≥16℃
850 650 400
Twh(℃) Twh <23℃ 23℃<Twh<29℃ Twh≥29℃
500 650 800
After 3 minutes,The wind speed control is related to the frequency of the compressor and the temperature
conditions of the outdoor environment.
Heating
Cooling\Dry