Functions and Control
Domestic air conditioner
19
7
.1.16 Single indoor system operation
* Enter condition: First, set the high speed airflow and 30 centigrade set temperature, then press th
e
dormant keys for 6 times within 7 seconds, the system will feedback with 6 rings.
* After the system enters the separate indoor system operation mode, the indoor system will operat
e
according to the set mode and neglect the communication signals of the outdoor system. However, i
t
has to send signals to the outdoor system.
* Quitting condition: This mode can be quitted after receiving the quitting signal from the remote control
or urgency system. The indoor system thus can quit the single operation mode.
7
.1.17 Power cut compensation
* Entering condition: Press dormant button 10 times within 7 second, the buzzer will ring 4 times and th
e
present system status will be stored into the EEPROM of the indoor system.
* After entering the power cut compensation mode, the processing of the indoor system should be a
s
the followings:
Remote control urgency signal: operate according to the remote control and the urgent conditions, th
e
present status will be stored into the EEPROM of the indoor system.
* Quitting conditions: Press dormant button 10 times within 7 seconds and the buzzer will ring twice.
7
.1.18 Test program
First, connect the test program terminal on the mainboard. Then connect the system to the power circui
t.
The test program will operate as follows.
HV series display: The buzzer rings for one time—the signal will be sent to outdoor system for 0.
5
secondthe violet is sent for 0.5-- the background light turns to white—the back ground light turns t
o
white—the background light turns to white—the background light is fully lighted for 0.5 second—LE
D
screen lights for 0.5 second the step-in motor fully output for 0.5 second—then the motor doesn’t
output for 0.5 second—the motor fully output again for 0.5 second. The test program finishes.
7
.1.19 Time cutting function:
Connect the test program terminal on the mainboard after connecting the system to the power circuit
.
The CPU of the main control will be 60 times faster.
7
.1.20 Room card function:
1If the SW2 code chooses the room card is invalid(SW2_2 is OFF), the remote control, wire control
,
long-range control, room card (closed is on, disconnect is off) are effective.
2If the SW2 code chooses the room card is valid(SW2_2 is ON), you need to insert the room card
first.And then received the start signal of remote control, or wire control, or long-range control, th
e
machine can run.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier SUPER MATCH AS25S2SF1FA-BC and is the answer not in the manual?

Haier SUPER MATCH AS25S2SF1FA-BC Specifications

General IconGeneral
BrandHaier
ModelSUPER MATCH AS25S2SF1FA-BC
CategoryAir Conditioner
LanguageEnglish

Related product manuals