EasyManua.ls Logo

HandyWave HPS-120 - Command Set Overview

Default Icon
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
4.3. Command Set
4.3.1. Command List for Local Device
Item Syntax Description Remarks
1. Connecting
address
AAddr<Enter> Set a remote device
address for a wireless
connection.
A local and remote
BD_ADDR always need to
be difference.
2. Baud rate BBaud Rate Change the baud rate Baud Rate - 0: 1200, 1:
2400, 2: 4800, 3: 9600, 4:
19200, 5: 38400, 6: 57600,
7: 115200
3. COM port CCOM Port
This is only valid in connection
mode 2.
4. PIN code EPIN<Enter>
Authentication Off: Type <Enter>
Authentication On: Type up to 11
characters
Paired adapters should
have a same PIN code.
5. Flow control FFlow Control
Set the Flow control.
0: None, 1: Hardware, 2:
DTR/DSR, 3: Hardware &
DTR/DSR
6. Connection
mode
Mmode Set a connection mode 0: 1:1 Mode, 1: WAIT Mode,
2: REGISTER and
CONNECT Mode
7. Friendly name Nname<Enter> Set a friendly name up to 11
characters.
8. Command for
the remote
O Enter configuration mode
for the remote.
9. Parity Bit Pparity Set the parity bit. 0: None, 1: Odd 2: Even
10. Stop Bit Sstop Set the stop bit. 0: 1 Stop, 1: 2 Stop
11. View V Display configuration
information
12. Exit X Apply changes.
13. Usage ? Print the usage.
Waning!
If you push the RST button, the COM port of HPS-120 will be stored the factory setting.

Related product manuals