e. Remove the insulation [1].
f. Loosenthescrews[2]ofthelterhousing.Caution
is necessary as the system may still be under slight
residual pressure.
g. Removeallscrewsexceptoneandswingange[3]
to the side.
h. Pull out the old cartridges [4].
i. Push new cartridges on to the mounting posts in the
bottom of the separator vessel.
NOTE: Do not touch the foam sleeves of the
cartridgeswithyourngers.
j. Close housing in reverse order.
k. Put on insulation.
l. Switch on the dryer.
m. Repressurize the dryer by slowly opening the
compressed air inlet valve.
n. Slowly open the compressed air outlet valve.
o. Slowly close the compressed air bypass valve (if
equipped).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HANKISON SPX HES1000 and is the answer not in the manual?

HANKISON SPX HES1000 Specifications