EasyManuals Logo

Hanna Instruments HI 83141 User Manual

Hanna Instruments HI 83141
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instruction Manual
HI 83141
Portable pH/mV/ºC meter
www.hannainst.com
WARRANTY
All Hanna Instruments meters are warranted for two years against
defects in workmanship and materials when used for their intended pur-
pose and maintained according to instructions.
The electrodes and the probes are warranted for a period of six
months. This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed mainte-
nance are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase,
serial number and the nature of the failure.
If the repair is not covered by the warranty, you will be notified of the
charges incurred. If the instrument is to be returned to Hanna Instruments,
first obtain a Returned Goods Authorization Number from the Customer
Service department and then send it with shipment costs prepaid.
When shipping any instrument, make sure it is properly packaged for
complete protection.
Dear Customer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for the correct
operation of the meter. Please read it carefully before using the
meter. If you need additional technical information, do not
hesitate to e-mail us at tech@hannainst.com.
This instrument is in compliance with the directives.
Remove the instrument from the packing material and exam-
ine it carefully to make sure that no damage has occurred
during shipment. If there is any damage, notify your Dealer.
The meter is supplied complete with
• HI 1230B plastic-body, double-junction, gel, com-
bination pH electrode with BNC and 1 m cable
• HI 7669AW temperature probe with 1 m cable
• 1 x 9V battery, screwdriver and instructions.
Note: Conserve all packing material until the instrument has
been observed to function correctly. Any defective item
must be returned in its original packing.
PRELIMINARY EXAMINATION
FUNCTIONAL DESCRIPTION SPECIFICATIONS
1) BNC connector for pH (or ORP) electrode.
2) Liquid Crystal Display.
3) mV key, to display the mV (ORP) readings when using
an ORP electrode or the mV equivalent to pH values
when using a pH electrode.
4) Trimmer for pH OFFSET calibration.
5) Trimmer for pH SLOPE calibration.
6) °C key, to display the temperature measurement.
7) pH key, to display the pH value.
8) ON/OFF key.
9) Socket for HI 7669AW temperature probe.
Range 0.00 to 14.00 pH
±1999 mV
0.0 to 100.0°C
Resolution 0.01 pH / 1 mV /0.1°C
Accuracy (@20°C/68°F) ±0.01 pH / ±1 mV
±0.4°C
Typical EMC Deviation ±0.07 pH / ±5 mV / ±1°C
pH Calibration Manual, at 2 points through
offset and slope trimmers
Offset Calibration ±1 pH
Slope Calibration from 85 to 105%
ORP Calibration Factory calibrated
Temperature Calibration Factory calibrated
Temperature Compensation
Automatic, from 0 to 70°C
Probes (included) HI 1230B pH-electrode
HI 7669AW temperature probe
Battery Type 1 x 9V alkaline
Battery Life 100 hours of continuous use
Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Dimensions 164 x 76 x 45 mm
(6.5 x 3.0 x 1.8")
Weight 180 g (6.3 oz.)
ACCESSORIES
HI 1230B Plastic body, double-junction, gel, combination pH-
electrode with BNC connector and 1 m cable
HI 3131B Glass-body, refillable, combination platinum ORP-
electrode with BNC connector and 1 m cable
HI 7669AW Temperature probe with 1 m screened cable
HI 7004M pH 4.01 buffer solution, 230 ml bottle
HI 7006M pH 6.86 buffer solution, 230 ml bottle
HI 7007M pH 7.01 buffer solution, 230 ml bottle
HI 7009M pH 9.18 buffer solution, 230 ml bottle
HI 7010M pH 10.01 buffer solution, 230 ml bottle
HI 70300M Storage solution, 230 ml bottle
HI 7061M Cleaning solution, 230 ml bottle
HI 7091M Reducing pretreatment solution, 230 ml bottle
HI 7092M Oxidizing pretreatment solution, 230 ml bottle
HI 731326 Calibration screwdriver (20 pcs)
HI 76405 Electrode holder
Consult the Hanna General Catalog for a complete and
wide selection of electrodes.
Hanna Instruments reserves the right to modify the design, construction
and appearance of its products without advance notice.
Recommendations for Users
Before using this product, make sure that it is entirely suitable for the environment in which it
is used. Operation of this instrument in residential area could cause unacceptable interference to
radio and TV equipment, requiring the operator to take all necessary steps to correct interference.
The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid
touching this glass bulb at all times.
To maintain the EMC performance of equipment, the recommended cables noted in the user's
manual must be used. Any variation introduced by the user to the supplied equipment may
degrade the instruments' EMC performance.
To avoid electrical shock, do not use these instruments when voltages at the measurement surface
exceed 24Vac or 60Vdc. To avoid damage or burns, do not perform any measurement in microwave
ovens.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI 83141 and is the answer not in the manual?

Hanna Instruments HI 83141 Specifications

General IconGeneral
BrandHanna Instruments
ModelHI 83141
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals