Page EN-30 Fitting and installation
– Your built-in furniture may need to be mod-
ified. If you do not have the manual skills
to do this, you should hire a professional.
– Veneers or plastic coverings on the built-
in furniture require heat-resistant adhesive
(100 °C). If the adhesive and surfaces are
not heat-resistant, the covering may warp
and come loose.
– An intermediate shelf is required if a draw-
er is to be installed below the oven.
– The installation recess may not have a rear
panel, at the most it may have an add-on
edge measuring no more than 50 mm.
– The built-in cabinet can be equipped with
either ledges/rails or an intermediate shelf
with ventilation cut-out.
➋
➊
➏
➐
➍
➎
➌
– The installation recess must have the fol-
lowing minimum dimensions:
❶ 600 mm
➋ 606 mm
❸ 560 mm
➍ 575 mm
❺ 600 mm
❻ max. 50 mm
➐ max. 50 mm
Smallest conductor cross-section
Rated current of
the device in A
Nominal cross sec-
tion in mm
2
> 3 and ≤ 6 0.75
> 6 and ≤ 10 1.0
> 10 and ≤ 16 1.5
> 16 and ≤ 25 2.5
> 25 and ≤ 32 4
> 32 and ≤ 40 6
> 40 and ≤ 63 10
230 V 1N~ / 50 Hz
L1
N
PE
3
2
1
4
5
L1 to (bridged)
N to
(bridged)
(PE) to
400 V 2N~ / 50 Hz
L2
L1
N
PE
3
2
1
4
5
L1 to
L2 to (bridged)
N to
(bridged)
(PE) to
400 V 3N~ / 50 Hz
L2
L3
L1
N
PE
3
2
1
4
5
L1 to , L2 to , L3 to
N to (bridged)
(PE) to
L1 – L3: Phase(s), N: Neutral conductor,
PE: Protective conductor (earth wire).
Installing the oven
The following conditions must be observed:
– Do not install the oven directly next to a
refrigerator or freezer. This will increase its
energy consumption unnecessarily due to
heat emission.
– The best place is next to the sink. You have
an additional work surface and dirty dishes
can be washed immediately.
– Before installation, check whether the ap-
pliance dimensions are compatible with
your furniture dimensions.
– In respect of fire protection, the oven con-
forms to Type Y (EC 335-2-6). This type
of appliance may only be installed on one
side of taller kitchen cabinets, appliances
or walls.