4
MD MD MD MD
MD
MD MD MD
Change set value in POND / PINT / SOND / SINT / SOFD / S.OND / S.INT / S.ODR operation modes
Change set value in PFKF / PFKN / TWON / TWOF / S-D / SFKF / SNFN / SNFF / S.FKN operation modes
Function setting mode
● When using POND / PINT / SOND / SINT / SOFD / S.OND / S.INT / S.ODR operation modes,
the time value is displayed on PV display, and the set value is displayed on SV display.
● The operating time timing is performed also during set value change.
● If there is no key input for more than 1 minute, it returns to operation mode without saving the set value.
● If you press
in operation mode, it enters to set value change mode, and the first digit of SV display flashes.
● Use to move to the position of the digit that you want to change, and use / to change the set value.
● After changing the set value, press
to save the changed set value and return to operation mode.
● If set value is ‘0’, even if you press it does not return to operation mode (you can set ‘0’ in POND / SOND / S.OND / S.ODR operation modes)
● When using PFKF/TWOF/SFKF/SNFF operation modes, OFF time set value is displayed
on PV display, and ON time set value is displayed on SV display.
● When using PFKN / TWON / S-D / SNFN / S.FKN operation modes, ON time set value
is displayed on PV display, OFF time set value is displayed on SV display.
● The operating time timing is performed also during ON time set value and OFF time set
value change.
● If there is no key input for more than 1 minute, it returns to operation mode without
saving the set value.
● If you press
in operation mode, it enters to set value change mode, and the first
digit of PV display flashes.
● Use
to move to the position of the digit that you want to change, and use /
to change the set value.
● After changing the set value of PV display, you can change set value of SV display by
pressing
.
● After changing the set value of SV display, press to save the changed set value
and return to operation mode.
● If ON time set value and OFF time set value are ‘0’, even if you press it does not
return to operation mode.
● Press and hold for at least 3 sec. in operation mode, to enter function setting mode.
● Press and hold for at least 3 sec. in function setting mode to save the changed function mode, and return to operation mode.
● You can switch the function mode with .
● The OUTT (output time) function is displayed only when the operation modes are POND, SOND, S.OND, S.ODR.
● The P.RNG (PV time range) function is displayed only when the operation modes are PFKF, PFKN, TWON, TWOF, S-D, SFKF, SNFN, SNFF, S.FKN.
● The CONT (contact configuration) function is only displayed on LT4 models.
● The IN-T (input minimum time) function is only displayed on the LT4S models.
operation mode
PV display
SV display
enter set value
change mode
move
move move move move
move
move
move
Move to SV display
Move to SV display
Move to SV display
Move to SV display
MD
MD MD
MD MD
MD
MD MD MD MD MD
MD MD MD
MD MD MD
MD
operation mode
PV display
SV display
3 sec. min.
select operation mode
Select output time
Select numeral system
Select addition/subtraction
Select PV time range
Enter
function
setting
mode
3 sec. min.
3 sec. min.
3 sec. min.
3 sec. min.
3 sec. min.
3 sec. min. 3 sec. min. 3 sec. min.
3 sec. min.
Select lock
Select input min. time Select contact configuration Select SV time range
save set value
save set value
save set value
save set value
MD
MD MD
MD
operation mode
PV display
SV display
enter set value
change mode
move move move move
save set value
save set value
save set value
save set value
Set value configuration
LT4 LT4S
Parameter PV display SV display Parameter PV display SV display
POND - t SOND - t
PFKF Toff Ton SFKF Toff Ton
PFKN Ton Toff SINT - t
PINT - t SNFN Ton Toff
TWON Ton Toff SNFF Toff Ton
TWOF Toff Ton SOFD - t
S-D Ton Toff S.OND - t
- - - S.FKN Ton Toff
- - - S.INT - t
- - - S.ODR - t
* t : set time, Ton : ON set time, Toff : OFF set time