Page 13
For technical questions, please call 1-888-866-5797.
ITEM 57080
SAFETYOPERATIONMAINTENANCE SETUP
Overload Indicator
Note: The OVERLOAD light may turn on for a few seconds as a large device starts up.
This is normal for loads approaching the capacity of this Generator.
1. The total combined load through the
outlets on the Generator must not exceed
the running power of the unit.
2. If the OVERLOAD light turns on and the Generator
stops producing power, it has been overloaded.
3. Turn off and disconnect all electrical devices and
stop the Engine. Compare device requirements
to Generator rating and reduce the total wattage
of connected devices if necessary. Move anything
that may be limiting Generator ventilation away.
4. Check if any circuit breakers have tripped
and make sure that ALL circuit breakers are
reset before starting the Generator again.
5. Restart the Engine and reconnect devices while
being careful to not overload Generator.
Low Oil Indicator
1. If the Engine oil level is too low, the LOW OIL light
turns on and the Engine will automatically shut off.
2. The Engine cannot be restarted until the proper
amount of oil has been added. Add the appropriate
type of oil until the oil level is at the proper level.
SAE 10W-30 oil is recommended for general use.
NOTICE: Do not run the engine with too little oil.
Engine will shut off if engine oil level is too low.
Economy (ESC) Switch
1. Turn the Economy (ESC) Switch ON to limit noise
and fuel consumption for lighter generator loads.
2. Turn the Economy (ESC) Switch OFF
to operate engine at full speed:
a. when starting
b. when a heavy load is applied
c. when using the 12 VDC output
Digital Display Screen
The Display Screen can be used to monitor
the operating status of the Generator.
Use the Display Control Button to scroll
through the following indicators:
V – Voltage
A – Amperage
VA – Volt Amps / Watts
Hour – accumulative run time