7 - Fault finding
80
Mechanical problems
Emergency operation - Liquid system
In case of power failure it is possible to operate all functions of the operating unit manually. First disconnect the multi-plug
from the control box. Now manually turn the emergency control knobs.
The problem may be due to a blown fuse. A fuse is placed inside the box. Fuse type: Thermo
Emergency operation - EasyClean filter
If difficulties occur with opening the filter and closing the built-in valve,
use a 13 mm wrench on the key profile (A).
Also the filter can be drained before filter element at the drain plug (B).
±
WARNING! Always wear protective clothing and gloves before
opening the filter!