HARDY MANUFACTURING CO., INC (MODEL H25) PAGE 29
Section VII 7-5 Trouble Shooting Guide H25
Grates
1 Grates stopped up
1 Clear grates of ash buildup.
If grates are warped, turn
them over and allow to
straighten.
Air intake 1 Air intake stopped up 1 Clean air intake at back of
heater of any obstructions.
Damper Chamber 1 Damper chamber
stopped up
1 Lift damper lid and check
for obstructions.
Forced Air Blower 1 Forced air blower not
running
1 If not running see No Heat
section in this guide
Smoke Stack 1 Smoke stack stopped
up
1 Remove smoke stack and
check for creosote build up.
Baffle 1 Baffle blocked 1 Clean out fire box and check
openings to baffle plate
Improper
Burning
Remove all the
ashes and wood
Fire 1 Fire goes out 1 If fire goes completely out
when damper is closed,
check the holes in the
damper lid for obstructions,
clean out.
Moisture
In Fire Box
Firebox 1 Yearly startup
2 Green Wood
1 The firebox walls will sweat
and water will run down the
sides. This should clear up in
a few days.
2 Green wood will create
excess moisture.
COMPLAINT AREA OF TROUBLE POSSIBLE CAUSES CORRECTIVE ACTION

Related product manuals