Harman® • Accentra 52i Owner’s Manual_R8 • 2013 -___ • 07/1417 3-90-00574c
C. General Maintenance
Types of Fuel
The type of fuel you are burning will dictate how often you
have to clean your burnpot.
If the fuel you are burning has a high dirt or ash content or
you are burning shelled eld corn, it may be necessary to
clean the burnpot more than once a day.
Dirty fuel will cause clinkers to form in the burnpot. A clinker is
formed when dirt, ash or a non-burnable substance is heated
to 2000° F (1093° C) and becomes glass-like.
Once a year the removal of the replace insert should be done
for the purpose of inspecting the replace insert and replace.
Be sure to inspect and clean exhaust venting system
regularly.
B. Quick Reference Maintenance Chart
Follow the detailed instructions found in this section
for each step listed in the chart below.
Cleaning or Inspection
Frequency Daily Weekly Monthly Yearly
Ash Pan Every 10 bags of fuel
depending on the fuel type or
ash build-up
OR X
Ash Removal from Firebox Every 5 bags or more
frequently depending on the
fuel type or ash build-up
OR X
Heat Exchanger Every 1 ton of fuel OR X
Blower, Combustion (Exhaust) More frequently depending on
the fuel type
OR X
Blower, Distribution Prior to heating season OR X
Door Gasket Inspection Prior to heating season OR X
Exhaust Path More frequently depending on
ash build-up
OR X
Firebox - Prepare for Non-Burn Season At end of heating season OR X
Burnpot - Burning pellets - hardwood Every 3 bags OR X
Burnpot - Burning pellets - softwood Every 5 bags OR X
Glass When clear view of burnpot
becomes obscure
OR X
Hopper / Hopper Lid Gasket Every 50 bags of fuel or when
changing fuel types
OR X
Venting System More frequently depending on
the fuel type
OR X
NOTICE: These are recommendations. Clean more frequently if you encounter heavy build-up of ash at the recommended
interval or you see soot coming from the vent. Not properly cleaning your appliance on a regular basis will void your
warranty.
5
Maintenance & Service
Shock and Smoke Hazard
Turn unit to the off position, let appliance
completely cool and combustion blower must
be off. Now you can unplug appliance before
servicing.
Smoke spillage into room can occur if
appliance is not cool before unplugging.
Risk of shock if appliance not unplugged
before servicing appliance.
A. Proper Shutdown Procedure
CAUTION
!
When properly maintained, your stove will give you many
years of trouble-free service. Contact your dealer to answer
questions regarding proper operation, trouble-shooting and
service for your appliance. Visit www.harmanstoves.com to
nd a dealer. We recommend annual service by a qualied
service technician.

Other manuals for Harman Accentra 52i

Related product manuals