Troubleshooting and Frequently Asked Questions
A. Error Code Description
Status light error messages:
3 Blinks: Indicates that the ESP (Exhaust Sensing Probe)
has failed, has a broken connection, or has gone out of range
too many times. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed. If a
Room Sensing Probe is then installed, the status light will
automatically reset.
NOTE: Unit will not start in "AUTO" with this status error.
5 Blinks (In Igniter Auto. Mode Only): Indicates that the unit
has failed to light within the 36 minute start cycle. To reset -
Turn Mode Selector to "OFF", then turn to either mode again.)
6 Blinks : Indicates that the control has calculated poor or
incomplete combustion occurring for more than 25 minutes.
A six blink status may occur if the stove is allowed to run out
of pellets. To reset, turn mode selector to "OFF" then back
on to the desired mode.
* Manual reset - disconnect power cord for a few seconds
and reconnect. If error still occurs call your Dealer.