B. Quick Reference Maintenance Chart
Follow the detailed instructions found in this section
for each step listed in the chart below.
Cleaning or Inspection
Frequency Daily Weekly Monthly Yearly
AshPan Every5bagsoffueldepending
onthefueltypeorashbuild-up
OR X
AshRemovalfromFirebox Every5bagsormore
frequentlydependingonthe
fueltypeorashbuild-up
OR X
HeatExchanger Every1tonoffuel OR X
Blower,Combustion(Exhaust) Morefrequentlydependingon
thefueltype
OR X
Blower,Distribution Every25bagsormore
frequentlydependingonthe
fueltype
OR X
DoorGasketInspection Priortoheatingseason OR X
ExhaustPath Morefrequentlydependingon
ashbuild-up
OR X
Firebox-PrepareforNon-BurnSeason Atendofheatingseason OR X
Burnpot-Burningpellets-hardwood Every3bags OR X
Burnpot-Burningpellets-softwood Every5bags OR X
Glass Whenclearviewofburnpot
becomesobscure
OR X
Hopper/HopperLidGasket Every50bagsoffuelorwhen
changingfueltypes
OR X
VentingSystem Morefrequentlydependingon
thefueltype
OR X
5
Maintenance & Service
A. Proper Shutdown Procedure
C. General Maintenance
Types of Fuel
Thetypeoffuelyouareburningwilldictatehowoftenyouhave
tocleanyourburnpot.
Ifthefuelyouareburninghasahighdirtorashcontent,itmay
benecessarytocleantheburnpotmorethanonceaday.
Dirtyfuelwillcauseclinkerstoformintheburnpot.Aclinkeris
formedwhendirt,ashoranon-burnablesubstanceisheated
to 2000°F(1093°C)andbecomesglass-like.
Enamel Touch-Up
Enameltouchuppaintisprovidedforxingminorenamel
chipsorblemishesthatmayoccurafterstoveinstallation.
Unfortunately, because the enamel nish of your stove is
a baked on glass nish, this enamel touch up paint may
notbeaperfectmatchtothecolorandglossoftheoriginal
factorynish.Tousethistouchuppaint:Ensurethestove
iscoolandthatthesurfacetobepaintedisclean.Applyin
severallightcoatsandtakecaretoonlycoatthechipped
area.Allowthepainttodryfor24hoursbeforetouchingor
ringthestove.
Whenproperlymaintained,yourstovewillgiveyoumany
yearsoftrouble-freeservice.Contact your dealertoanswer
questionsregardingproperoperation,trouble-shootingand
serviceforyourappliance.Visitwww.harmanstoves.comto
ndadealer.Werecommendannualservicebyaqualied
servicetechnician.
Shock and Smoke Hazard
• Turnunittotheoffposition,letappliance
completelycoolandcombustionblowermust
beoff.Nowyoucanunplugappliancebefore
servicing.
• Smokespillageintoroomcanoccurifappliance
isnotcoolbeforeunplugging.
• Riskofshockifappliancenotunpluggedbefore
servicingappliance.
CAUTION