Harman®  •  Accentra Owner’s Manual_R40  •  2002 -___  •  11/154 3-90-08326c
2 
Product Specic and Important Safety Information 
A.  Appliance Certication B.  Mobile Home Approved
This appliance is approved for mobile home installations
whennotinstalledinasleepingroomandwhenanoutside
combustionairinletisprovided.
Thestructuralintegrityofthemobilehomeoor,ceiling,and
wallsmustbemaintained.Theappliancemustbeproperly
groundedtotheframeofthemobilehomeanduseonlylisted
pelletvent,Class“PL”connectorpipe.
A Harman® OutsideAir Kit must be installed in a mobile
homeinstallation.
NOTE:  Thisinstallationmustconformwithlocalcodes.
In the absence of local codes you must comply with
the  ASTM E1509-2004, ULC S628-93, ULC/ORD-C-
1482-M1990, (UM) 84-HUD 
THE STRUCTURAL INTEGRITY OF THE 
MANUFACTURED HOME FLOOR, WALL, AND 
CEILING/ROOF MUST BE MAINTAINED.
DO NOT INSTALL IN SLEEPING ROOM.
WARNING
TheAccentra is Certied to comply with
2015particulateemissionstandards.Not
approvedforsaleafterMay15,2020.
MODEL: AccentraPelletStove
LABORATORY: OMNITestLaboratories,Inc
REPORT NO. 135-S-10b-2
TYPE: PelletFueled/SupplementaryFor
ResidentialUse
STANDARD(s): ASTME1509-04,ULC/ORD-
C1482-M1990,ULC-S627-00,
ASTME2779-10,ASTME2515-11
ELECTRICAL 
RATING
115 VAC, 60 Hz, Start 4.2 AMPS,
Run3.6AMPS
GLASS 
SPECIFICATIONS
5mmCeramicGlass