11
KM200 System
Setup the Working Frequency
1. Setup Manually
• Press the “Up/Down Navigation Key” on the SR200 to select the RF channel you would like to use;
• Power on the HT200 and aiming the IR sensor on the HT200 to the SR200 IR sensor position;
• Long Press “Up Navigation Key” on the SR200 for 3 seconds, and the LCD screen will display “ “ and start
blinking, it means under channel synchronization process.
• While the synchronization process is done, the channel on HT200 will be adjusted to the same as on SR200, and the
RF indicator will be on.
2. Setup Automatically
• Press the “Function Key” on the SR200, and the LCD screen will display “CH SCA“;
• Press the “Up/Down Navigation Key” to activate the scan process, SR200 will scan the 1st 50 channels for clean
channel, while the clean channel is found, SR200 will stop scanning and display this Clean Channel, if no clean
channel found, SR200 will stop and standby, waiting for the user to press “Up/Down Navigation Key” to activate the
scan process for next 50 channels (ie, every 50 channel scan, SR200 will stop and stand by for activation for next 50
channel scan);
• Power on the HT200 and aiming the IR sensor on the HT200 to the SR200 IR sensor position;
• Long Press “Up Navigation Key” on the SR200 for 3 seconds, and the LCD screen will display “ “ and start
blinking, it means under channel synchronization process.
• While the synchronization process is done, the channel on HT200 will be adjusted to the same as on SR200, and the
RF indicator will be on.
SETUP The System
IR Sensors