Harman®  •   Owners anualR2  •  200 -  •  0811 0 3 -9 0 -0 0 6 8 4 c
E.  Before Y our F irst F ire
1.  irst,  make  sure  your  appliance  has  been  properly 
installed and that all safety requirements have been met.  
Pay particular attention to the re protection and venting 
instructions.
2.  ouble check that the ash pan and rebox are empty
.  Close the front door.
ire Hazard.
eep combustible materials, gasoline 
and other ammable vapors and liquids 
clear of appliance.
E.  G eneral Operating Information
1 .  R oom Sensor Calls F or Heat
The appliance is like most modern furnaces when the room 
sensor calls for heat, your appliance will automatically light 
and deliver heat.  
When the room is up to temperature and the room sensor is 
satised, the appliance will shut down.
2 .  Heat Output Controls
The  appliance  will  turn  on  and  off  as  the  room  sensor 
demands.  When the room sensor calls for heat, the appliance 
will always start up on High.  After burning approximately 7-10 
minutes, the appliance will then burn at the rate at which it 
was originally set. If the appliance is set at one of the lower 
settings, it will run quieter but take longer to heat up an area 
than if it were set at a higher burn rate.  
Regardless of the burn rate, when the area is warm enough 
to satisfy the room sensor, the appliance will shut off.
W AR NING
•  o NOT store ammable materials in the appliances vicinity.
•  NEER  USE  GASOLINE,  GASOLINE-TYPE  LANTERN 
UEL,  EROSENE,  CHARCOAL  LIGHTER  LUI,  OR 
SIILAR LIUIS TO START OR RESHEN UP A IRE 
IN THIS HEATER. EEP ALL SUCH LIUIS WELL AWAY 
RO THE HEATER WHILE IT IS IN USE.
•  O NOT BURN GARBAGE OR LAABLE LUIS SUCH 
AS GASOLINE, NAPHTHA OR ENGINE OIL.
•  O  NOT  USE  CHEICALS  O LUIS TO  START THE 
IRE. 
•  Combustible materials may ignite.
F igure 3 .1