Loading...
RF-5800H 125-WATT COMMUNICATION SYSTEM
INSTALLATION
2-24
e. Press the ENT pushbutton.
f. If necessary, press the left/right arrow pushbuttons to select the ALL field.
g. Press the ENT pushbutton.
h. If the unit passes BIT, place in service. If a BIT code is displayed refer to the following paragraphs.
If the RF-5800H-MP displays a fault code on the LCD after completing the BIT test, record the fault
code and proceed to Paragraph 6.2.4, BIT Troubleshooting.
If the RF-5800H-MP displays no error messages, try to operate the RF-5800H 125-Watt Communication
System in an attempt to generate a run-time fault. If a run-time fault is generated, refer to the non-BIT
troubleshooting procedures in Paragraph 6.2.3.
If a run-time fault cannot be generated and the RF-5800H 125-Watt Communication System is still not
operating properly, refer to the non-BIT troubleshooting procedures in Paragraph 6.2.3.