EasyManua.ls Logo

Harris RF-5832H-PA - Chapter 5 Scheduled Maintenance; 5.1 Preventive Maintenance

Default Icon
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RF-5800H 125-WATT COMMUNICATION SYSTEM
SCHEDULED MAINTENANCE
5-1
CHAPTER 5
SCHEDULED MAINTENANCE
5.1 PREVENTIVE MAINTENANCE
Preventive maintenance is the systematic, daily care and inspection of equipment to prevent equipment failure and
reduce downtime.
Table 5-1 contains the checks and services that should either be performed on a daily basis when the equipment is
in use or on a weekly basis when the equipment is in a standby condition. Table 5-2 contains the checks and
services that should be performed on a weekly basis.
Table 5-1. Daily Preventive Maintenance Checks and Services
Check No.
Item to be Inspected Procedure
1 Completeness Check to see that the equipment is complete.
2 Exterior Surfaces Remove dust, dirt, and moisture from all surfaces and clean
front panel display window with a soft cloth.
3 Controls Check all controls for looseness or damage; check mechanical
action of each control for smooth operation.
4 Fan Remove dust and dirt. Check if fan turns freely.
5 Operation Perform self-test.
Table 5-2. Weekly Preventive Maintenance Checks and Services
Check No.
Item to be Inspected Procedure
1 Connectors Check all connectors for debris, damage, or corrosion. Contact a
qualified Level III or Level IV maintainer if further repair is
required.
2 Antenna Check for breaks or strains; repair or replace as required.