RF-5800H 125-WATT COMMUNICATION SYSTEM
TROUBLESHOOTING
6-5
Table 6-1. Non-BIT Fault Symptoms/Run Time Fault Codes Continued
Symptom Observed
Action
Variable or no audio signals. Perform the following:
Check PA-R/T audio cable and
replace as necessary.
Replace RF-5800H-MP.
Replace RF-5832H-PA.
Accessory connected to RF-5832H-PA does not power up. Perform the following:
Check auxiliary power cable and
replace as necessary.
Replace RF-5832H-PA.
Suspected power output problem. Perform the following:
If possible, perform scheduled
maintenance tests. Refer to
RF-5800H-MP and RF-5832H-PA
Intermediate Maintenance
Manuals.
Check RF cables and replace as
necessary.
Check that DC input voltage is
within specification. Perform
check under both a loaded and
unloaded condition.
Replace RF-5832H-PA.
Replace RF-5800H-MP.
Suspected receive sensitivity problem. Perform the following:
If possible, perform scheduled
maintenance tests. Refer to
RF-5800H-MP and RF-5832H-PA
Intermediate Maintenance
Manuals.
Check RF cables and replace as
necessary.
Replace RF-5800H-MP.
Replace RF-5832H-PA.
RF-5800H-MP does not reach normal operational display. Perform the following:
Replace RF-5800H-MP.