Haswill STC-8080H - Function Menu Parameters; Temperature for Refrigeration Starts; Temperature for Refrigeration Stops; Temperature Calibration

Haswill STC-8080H
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
https://www.thermo-hygro.com
2 / 4
2. Function Menu
Code
Function
F1
Temperature for Refrigeration Starts
F2
Temperature for Refrigeration Stops
F3
Temperature Calibration
F4
Compressor Delay Time
F5
Over-temperature to Trigger Alarm (more than
F1)
F6
Alarm Delay Time
F7
Defrosting Cycle / Interval Time
F8
Defrosting Lasting Time
3. Configuration
The aimed temperature range was defined from “F1” to
f2”; you need to set both.
≥ F1, refrigeration starts.
≤ F2, refrigeration ends.
Step1
Hold the key for 3s, and the code F1 will
appear.
Step2
Press the or keys to get the aim
function you want to update;
Step3
Press the key to check the existing value;
Hold the key meanwhile press the or