3.4 Checking the correctness of assembly
After all cables are connected, the mechanism should be checked and tested.
1) Check that the arm works well and the door does not jam and does not fall out of the
guides.
2) Connect the power. As soon as the device is turned on, the 7-segment display will show
numbers from 9 to 0 and the bulb will turn on for 2 seconds. After the bulb goes out, the
display will show the sign '' - '' which means that the end positions should be
programmed. If the '' ׀׀ '' sign appears, it means that the end positions have been
programmed (they must be set anew for each gate).
3) After programming, check that the safety devices such as photocell and obstacle stop are
working properly. This very important test must be performed carefully, as the safety of
using the gate depends on the efficient operation of these devices. The overload sensor
contributes significantly to minimizing damage, but only the correct installation of the
photocells will ensure that the door can be stopped before it hits a person or vehicle. This
operation must be performed after programming the drive.
4. Programming and adjustment
4.1 Programming the opening and closing positions
Press and hold the SET button until the display shows the number 1.
Press and hold the UP button until the door is fully open.
Press the SET button, the display will show the number 2.
Press and hold the DOWN button until the door is fully closed. Releasing the DOWN button
should take place at the moment of touching the door to the threshold. Do not set the end
position to the so-called "pressure", because in normal operation the drive slows down
before the end position and may not reach such a set position and will not react until the
end positions are correctly set.
Press the SET button to complete programming. The door will open and close automatically.
After closing, the display should show '' || '' If `` - '' appears, repeat programming, paying
attention to the above point.
The door open and close positions have been set.
WARNING! Objects and people should not be near the gate during installation.
IMPORTANT! To ensure continued safety, safety systems should be checked regularly.
4.2 Adjusting the sensitivity oft he overload sensor
If necessary, the maximum engine power may only be adjusted by a qualified mechanic.
Press and hold the SET button until the display shows the number 3, release the button. The
device is in force regulation mode and shows the amount of force set.
Press the UP button to increase the force by one step, press DOWN to decrease it one step.
The maximum rank is 9, the minimum rank is 1.
Press the SET button to confirm the setting.
If it encounters an obstacle when closing the door, it will move back 15-20 cm.