    kathywestAug 12, 2025
    Why is the hydraulic pump on my Haulotte Group H14T Boom Lifts making an abnormal noise?
    • D
      Dustin NunezAug 12, 2025
      If the hydraulic pump on your Haulotte Group Boom Lifts is making an abnormal noise, it is likely due to not enough hydraulic oil. To fix this, top up the oil level.
  • R
    Regina WestAug 16, 2025
    Why is there no steering on my Haulotte Group Boom Lifts?
    • T
      Tracy SchneiderAug 16, 2025
      If there is no steering on your Haulotte Group Boom Lifts, the issue might be due to: * Not enough hydraulic oil: Top up the oil level. * 'Enable Switch' control validation device is not enabled: Enable the device and keep pressed down during movement.
  • W
    waynemooneyAug 20, 2025
    What to do if platform controls do not respond on Haulotte Group H14T without buzzer?
    • B
      brewerscottAug 20, 2025
      If the platform controls on your Haulotte Group Boom Lift do not respond and there is no buzzer, consider these potential causes: * **Ground control box selector key is set to ground control box position:** Turn the ground control box selector key to platform control box position. * **'Enable Switch' control validation device is not enabled:** Enable the device and keep pressed down during movement. * **Not enough hydraulic oil:** Top up the oil level.
  • T
    thomas33Aug 25, 2025
    Why is there no high speed on Haulotte Group Boom Lifts?
    • Z
      Zachary BurtonAug 25, 2025
      If there is no high speed on your Haulotte Group Boom Lifts, it may be because the platform is extended. Lower the boom as far as possible.
  • L
    Lindsey KingAug 27, 2025
    What causes low hydraulic pump pressure or power in Haulotte Group H14T?
    • L
      Leah Wong DVMAug 27, 2025
      Low hydraulic pump pressure or power in your Haulotte Group Boom Lifts can be caused by: * Clogged air filter: Replace the filter. * Clogged oil filter: Replace the oil filter cartridge.
  • A
    annjosephAug 31, 2025
    What causes hydraulic pump cavitation in Haulotte Group H14T?
    • O
      oedwardsAug 31, 2025
      Hydraulic pump cavitation in Haulotte Group Boom Lifts is caused by oil viscosity level being too high. Drain the circuit and replace it with the recommended type of oil.
  • C
    Charles BaileySep 4, 2025
    Why is there no turntable rotation on my Haulotte Group H14T?
    • J
      Jody HoustonSep 4, 2025
      If there is no turntable rotation on your Haulotte Group Boom Lifts, it's likely because the turntable rotation locking pin is inserted in the chassis. Remove the pin to resolve this.
  • S
    Stacy MartinezSep 8, 2025
    What to do if a drive wheel does not hold the road on Haulotte Group H14T Boom Lifts?
    • J
      Jermaine PetersonSep 8, 2025
      If a drive wheel on your Haulotte Group Boom Lifts does not hold the road, it may be due to insufficient load on one wheel. Press the differential locking selector to address this issue.