09/19 1200 Series Electric Water Coolers Page 10 of 21
OPTIONAL BOTTLE FILLER – ERROR CODE TABLE
TROUBLESHOOTING
Note: If the suggested items in the checklist fail to solve the problem, contact Haws Technical
Support at 1-800-766-5612.
E009 – COMPCY
Compressor is cycling too frequently
Clear error in programming mode and
power cycle unit and check error to validate.
Power cycle unit and ensure fan runs
initially for approximately 10 seconds.
Clean condenser fins of dust and debris.
Verify inlet water and ambient temperatures
are below specification maximum.
E012 – SENOB
Bottle filler sensor is obstructed
Clear error in programming mode and
power cycle unit and check error to validate.
Remove obstruction from aperture
Clean aperture with soft cloth that won’t
scratch aperture.
Check aperture for excessive scratches
E014 – RFID
RFID board lost communication
Clear error in programming mode and
power cycle unit and check error to validate.
Check cable connection to RFID board.