Temperature/Resistance /Voltage
All Hayward controls use a 10K thermistor sensors. When disconnected from the
control, the sensor will read 10K ohms at 25ºC/77ºF. Refer to the chart below for
the resistance at other temperatures. For a given temperature, the resistance
reading should be accurate to ±1%. For a given resistance reading, the tempera-
ture reading should be accurate to ±0.5ºF. All voltage measurements (DC) must
be made with the sensor connected to the control and should be accurate to ± 2%.
°F Ohms
V
olts °F Ohms
V
olts °F Ohms
V
olts °F Ohms
V
olts
1 82,719 4.46 41 25,391 3.59 81 9,076 2.38 121 3,679 1.34
2 80,142 4.45 42 24,704 3.56 82 8,861 2.35 122 3,602 1.32
3 77,656 4.43 43 24,037 3.53 83 8,651 2.32 123 3,527 1.30
4 75,255 4.41 44 23,391 3.50 84 8,447 2.29 124 3,454 1.28
5 72,937 4.40 45 22,764 3.47 85 8,249 2.26 125 3,382 1.26
6 70,698 4.38 46 22,156 3.45 86 8,056 2.23 126 3,312 1.24
7 68,535 4.36 47 21,566 3.42 87 7,867 2.20 127 3,244 1.22
8 66,447 4.35 48 20,993 3.39 88 7,684 2.17 128 3,177 1.21
9 64,428 4.33 49 20,438 3.36 89 7,506 2.14 129 3,112 1.19
10 62,479 4.31 50 19,900 3.33 90 7,333 2.12 130 3,049 1.17
11 60,595 4.29 51 19,377 3.30 91 7,164 2.09 131 2,987 1.15
12 58,774 4.27 52 18,870 3.27 92 6,999 2.06 132 2,926 1.13
13 57,014 4.25 53 18,377 3.24 93 6,839 2.03 133 2,867 1.11
14 55,313 4.23 54 17,899 3.21 94 6,683 2.00 134 2,809 1.10
15 53,669 4.21 55 17,435 3.18 95 6,530 1.98 135 2,752 1.08
16 52,078 4.19 56 16,985 3.15 96 6,382 1.95 136 2,697 1.06
17 50,541 4.17 57 16,548 3.12 97 6,238 1.92 137 2,643 1.05
18 49,054 4.15 58 16,123 3.09 98 6,097 1.89 138 2,591 1.03
19 47,616 4.13 59 15,711 3.06 99 5,960 1.87 139 2,539 1.01
20 46,225 4.11 60 15,310 3.02 100 5,827 1.84 140 2,489 1.00
21 44,879 4.09 61 14,921 2.99 101 5,697 1.81 141 2,440 0.98
22 43,577 4.07 62 14,543 2.96 102 5,570 1.79 142 2,392 0.97
23 42,318 4.04 63 14,176 2.93 103 5,446 1.76 143 2,345 0.95
24 41,099 4.02 64 13,820 2.90 104 5,326 1.74 144 2,299 0.93
25 39,919 4.00 65 13,473 2.87 105 5,208 1.71 145 2,254 0.92
26 38,777 3.97 66 13,136 2.84 106 5,094 1.69 146 2,210 0.90
27 37,671 3.95 67 12,809 2.81 107 4,982 1.66 147 2,167 0.89
28 36,601 3.93 68 12,491 2.78 108 4,873 1.64 148 2,125 0.88
29 35,565 3.90 69 12,182 2.75 109 4,767 1.61 149 2,084 0.86
30 34,561 3.88 70 11,882 2.72 110 4,664 1.59 150 2,044 0.85
31 33,590 3.85 71 11,589 2.68 111 4,563 1.57 151 2,005 0.84
32 32,648 3.83 72 11,305 2.65 112 4,464 1.54 152 1,966 0.82
33 31,737 3.80 73 11,029 2.62 113 4,368 1.52 153 1,929 0.81
34 30,853 3.78 74 10,761 2.59 114 4,274 1.50 154 1,892 0.80
35 29,998 3.75 75 10,500 2.56 115 4,183 1.47 155 1,856 0.78
36 29,169 3.72 76 10,246 2.53 116 4,094 1.45 156 1,821 0.77
37 28,365 3.70 77 9,999 2.50 117 4,007 1.43 157 1,787 0.76
38 27,587 3.67 78 9,758 2.47 118 3,922 1.41 158 1,753 0.75
39 26,832 3.64 79 9,525 2.44 119 3,839 1.39 159 1,720 0.73
40 26,100 3.61 80 9,297 2.41 120 3,758 1.37 160 1,688 0.72
Electronic Solar Control Center
Operation and Installation
Manual
AQ-SOL-LV
AQ-SOL-LV-TC
AQ-SOL-LV-SP
092008F RevG
Copyright © 2010 Hayward Inc.
www.haywardnet.com
620 Division St.
Elizabeth, NJ 07207
Aqua Solar
Question and Answer IconNeed help?

Do you have a question about the Hayward Aqua Solar and is the answer not in the manual?

Hayward Aqua Solar Specifications

General IconGeneral
BrandHayward
ModelAqua Solar
CategoryController
LanguageEnglish

Summary

System Specifications

Sensor Details

Details the types and number of sensors required for system operation and monitoring.

Troubleshooting Common Issues

Power LED Off Diagnosis

Steps to diagnose issues when the power indicator LED is not lit.

Pool Sensor Error Resolution

Describes troubleshooting steps for pool sensor open or short circuit errors.

Jumper Settings and Configuration

Recirculate Freeze Protection Setup

Details enabling freeze protection, sensor placement, and limitations.

Solar Override Functionality

Describes enabling solar override for filter pump operation during solar availability.

System Operation Guide

Setting Desired Pool Temperature

How to set and view the desired pool temperature using the control knob.

Installation Procedures

Sensor and Wiring Connections

Related product manuals