9
Beeper
Enabled
Toggle between
Enabled (default) and Disabled Beeper
When “Enabled”, the keypad will beep every time a key is pressed. If this audible indication
is not desired, select “Disabled”.
This function only applies to the display/keypad that you are currently using. You need to
set this option for each display/keypad in your system.
NOTE: This function is not supported on all display/keypads. If the “Enabled” selection is
not blinking, then the current software revision of that particular keypad/display does not
support the option and it will default to Beeper Enabled.
Teach Wireless
+ to start
Teach
Successful
Wireless
Teach
NOT Successful
Wireless
Teach Wireless
Base NOT Found
Press and hold
wireless button
Push to start process
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Move to previous/next menu item
Press any button on wireless remote
This menu will only appear if a wireless base station is connected to the ECOMMAND 4.
Perform this procedure each time a wireless remote control is added to the ECOMMAND 4
system. During this procedure the wireless remote “learns” and remembers the ID code for
the wireless base station connected to this particular ECOMMAND 4 unit and will reject
messages with any other ID codes. If “Base NOT found” is displayed, then the ECOMMAND
4 can not communicate with the transmitter/receiver base station attached to the main unit. If
“NOT Successful” is displayed, then the base station did not receive a signal from the
remote control. This may be due to the distance between the Base Receiver and the remote
device being too great or may be due to interference caused by other RF equipment operat-
ing in the neighborhood. Try changing the channel and then repeat the “Teach Wireless”
command.
Wireless
Channel: 1
Reteach all
wireless units
Confirm Change:
+ to proceed
Push to confirm the channel change
Change the desired wireless channel (1 - 5)
Move to previous (Teach Wireless) menu
If channel is changed, move to confirmation menu
Move to previous/next menu item
If channel is not changed, move to previous/next menu item
This setting changes the channel to be used by the wireless base station and remote(s). If
the channel is changed and confirmed, all of the wireless remotes will have to be retaught.
This menu will only appear if a wireless base station is connected to the ECOMMAND 4.
18
Super Chlorinate – if “Chlorinator” is enabled, this option allows the user to start a Super
Chlorinate cycle when the Lights button is pressed, rather than using the Settings Menu.
Note that only one button can be assigned to this function.
Lights Relay
This feature allows the user to select either “Standard” (default) or “Dimmer” type relay for
the Lights output. The optional AQL-DIM dimmer kit must be installed if “Dimmer” is
desired. When “Dimmer” is selected, and the Lights output is manually turned on, the “+”
and “-” buttons adjust the level from 20% to 100% (default). The level is saved for the next
time the lights are turned from off to on.
Lights Interlock
If enabled, this feature will override the function (Manual On/Off, Countdown Timer,
Timeclock) selected above and turn the lights relay off when: filter pump is off, first 3
minutes of filter pump operation (allows the pump to prime and get water flowing), when the
pool/spa suction return valves are in any position other than “pool only”, or for the first 3
minutes after solar turns on (allows air in the solar panels to be purged). Interlock is not
available for solar, low speed filter pump, super chlorinate or dimmer.
Lights Freeze Protection
This function helps protect equipment that is wired to the lights relay against freeze damage.
If Freeze Protection is enabled and the AIR temperature sensor falls below the selected freeze
temperature threshold, the ECOMMAND 4 will energize the lights relay. IMPORTANT: this
only enables operation of the lights relay during freeze--see the “Filter Pump Config.” menu
to enable freeze protection for the main circulation system.
Lights Pump Speed
This is the speed of the pump when the Lights output is on. The choices are the Settings
Menu speed and a speed that is unique to the Lights output only. The default selection is
“Settings Menu”. This is the speed of the pump that has been selected in the Settings Menu
for normal filter operation. If an alternate speed is desired when the Lights output is on, push
“+” or “-” and select from “Lowest” to “Highest” in 5% increments.
NOTE: The configuration parameters for the Aux2 output are the same as shown below for Aux1.
Aux1 Pump Spd
Settings Menu
Select between Settings Menu (default) and the desired pump speed
only if filter pump is set to variable
and relay type is set to standard
Move to previous/next configuration menu
Aux1 Config.
+ to view/change
Aux1 Function
Manual On/Off
Aux1 Relay
Standard
Push to access Aux options
Toggle between Standard (default) and Dimmer
Move to previous/next configuration menu
Move to next menu item or previous/next configuration menu
Aux1 Interlock
Disable
Aux1 Freeze
Disable
Toggle between Enabled and Disabled (default) Aux1 Interlock
Toggle between Enabled and Disabled Aux1 Freeze(default)
Move to next menu item
Move to previous/next configuration menu
for manual on/off, countdown
timer and timeclock functions
Move to next menu item
Rotates between
Manual On/Off (default), Countdown Timer,
Low Speed- Filter, Timeclock, Solar, and Super Chlorinate
for all functions except dimmer relay, solar
super chlorinate, and low speed
f
super chlorinate, and low speed
or all functions except dimmer relay,
WARNING: Do not use the ECOMMAND 4 to control an automatic pool cover.
Swimmers may become entrapped underneath the cover.
Aux1 Function
Manual On/Off (default)—the aux relay will alternate between turning on and off when the
aux button is pressed. There is no automatic control logic.