EasyManua.ls Logo

Hayward SP26115VSP - User Manual

Hayward SP26115VSP
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IS26115VSP Rev-A
Hayward Pool Products
620 Division St, Elizabeth, NJ 07201
Phone: (908) 351-5400
www.haywardpool.com
Super Pump
®
VS
Owner’s Manual
Model SP26115VSP
Super Pump VS Variable Speed Pump
Hayward’s Super Pump VS variable speed pump delivers incredible energy savings via its advanced
hydraulic design combined with a totally enclosed, permanent magnet motor. Super Pump VS is easily
installed either as a programmable stand-alone pump or with a Hayward or third party controller and
features an easy-to-use digital control interface that can be mounted in four different positions on the
pump or removed and mounted on the wall for total user convenience.
Note: To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and
completely. Unless otherwise stated, instructions in this manual apply to both pump models.
SAVE THIS INSTRUCTION MANUAL

Table of Contents

Questions and Answers

  • M
    Margaret JohnsonAug 19, 2025
    How to troubleshoot a Hayward SP26115VSP Water Pump motor that will not start?
    • J
      jtoddAug 19, 2025
      If your Hayward Water Pump motor won't start, begin by ensuring the terminal board connections align with the wiring diagram on the pump's data plate label. Verify the pump is wired for the correct available field supply voltage (230VAC). Check for any loose or improper wiring connections, open switches or relays, tripped circuit breakers, or blown fuses and correct them. Manually inspect the motor shaft's rotation to ensure free movement without obstructions.
  • D
    Donald StephensAug 22, 2025
    How to fix low flow in my Hayward Water Pump?
    • A
      April DanielAug 23, 2025
      To address low flow in your Hayward Water Pump: * Ensure the piping size is correct. * Check for plugged or restricted discharge lines, or partially closed valves. For sand filters and D.E. filters, backwash according to the manufacturer's instructions. For cartridge filters, clean or replace the cartridge. * Re-tighten the suction and discharge connections using Teflon tape. * Consider replacing the impeller, including a new seal assembly.
  • R
    Randall AnthonyAug 26, 2025
    Why does my Hayward SP26115VSP motor keep shutting off?
    • R
      Rachael SimonAug 26, 2025
      A frequent cause for a Hayward Water Pump motor shutting off is undersized wiring. Check for low voltage or power drop at the motor. Contact a qualified professional to verify the electrical connections.
  • S
    Sandra JenningsAug 28, 2025
    How to reduce noise from my Hayward SP26115VSP Water Pump?
    • B
      Breanna YuAug 28, 2025
      To reduce noise from your Hayward Water Pump: * Correct the suction condition or throttle return lines, if practical. * Mount the pump on a level surface and secure it to the equipment pad. * Clean the pump housing. * Replace all seal leaks immediately.
  • S
    stoutcalebAug 31, 2025
    What to do if my Hayward SP26115VSP motor hums but doesn't start?
    • S
      Susan HortonAug 31, 2025
      If your Hayward Water Pump motor hums but doesn't start, the impeller may be jammed with debris. Have a qualified repair professional open the pump and remove the debris.
  • M
    Maureen HamiltonSep 2, 2025
    How to stop my Hayward SP26115VSP Water Pump from interfering with home automation equipment?
    • H
      Haley MillerSep 2, 2025
      To prevent your Hayward Water Pump from interfering with home automation or power line communication equipment: * Make sure the terminal board connections agree with the wiring diagram on the pump data plate label. * Check for and correct any improper or loose wiring connections. * Install a noise filter (from the home automation/power line communication equipment vendor).
  • R
    Rebecca McguireSep 5, 2025
    What to do if the Hayward SP26115VSP system DC voltage is too high?
    • A
      Ashley Lopez MDSep 5, 2025
      If the Hayward Water Pump system DC voltage is too high, verify that the line voltage is within 10% (104-126 VAC) of the pump rated voltage at the terminal block.
  • B
    Brandy BrooksSep 8, 2025
    What should I check if my Hayward Water Pump system drive is overloaded?
    • C
      christinegambleSep 8, 2025
      If the Hayward Water Pump system drive is overloaded, check the impeller, diffuser, shaft seal, and motor for any issues or binding.
  • A
    Alexander JonesSep 12, 2025
    What to check if Hayward SP26115VSP system failed to start?
    • D
      delacruzshaneSep 12, 2025
      If the Hayward Water Pump system failed to start, check the impeller, diffuser, shaft seal, and motor for any issues or binding.
  • J
    James MillerSep 13, 2025
    What to verify if the Hayward Water Pump system communication failed?
    • A
      Anthony ChristianSep 13, 2025
      If the Hayward Water Pump system communication failed, the connections between the user interface and motor/drive should be verified.