5/31/96
20
charging A hrs as positive. When the battery is charged, turn off the charging source. After
discharging begins the LINK 2000 automaticaly resets to zero, starts counting down, and
is in sync.
If the LINK 2000 Meter should ever get out of sync with the battery state of
charge it must be resynchronized. The best way is to be sure the battery is discharged
at least 10% of the declared battery capacity and then recharge until the charged
parameters are met. At this point the meter should reset to zero.
Remember occasional controlled overcharging ensures that the LINK 2000 Meter
is in sync with the batteries' state of charge.
RESETTING A HRS TO ZERO
If you want to manually reset your LINK 2000 to zero:
1) First select the battery you wish to reset.
2) Press the SET UP button for five seconds, when the LED begins flashing, release the
buton.
3) Press and hold the RESET A hrs button for three seconds (until the normal display
returns) to reset the A hrs of the selected battery to zero.