ADVANCED FUNCTIONS
The drawing below shows the Advanced Functions layout. To access these press the
SET UP BUTTON for ten seconds. The time is long to avoid unintentionally entering this
mode. When the green LED begins to
flash quickly (about 3 times per second) select the
Advanced Function you wish by consulting this drawing. The display returns to the
monitoring mode 5 seconds after the selected function button is released.
# LOW BAT/ # OL: The number of Inverter Low Battery shut downs (since last reset)
is displayed with a minus sign (negative number). The number of Inverter shut downs (since
last reset) from other causes are displayed with no sign (positive number). The display
alternates at three second intervals until the button is released.
SOFTWARE INFO: The revision number of the LINK-2000 software is displayed.
FLASH ALL LEDS & SEGMENTS: This display test continues until the button is
released.
RESET TO FACTORY DEFAULTS: When this button is held down for 5
seconds, all of the values set up for the selected battery are reset to the factory values.
A 0 (zero) should appear briefly in the display (watch closely). All historical data is
lost!! Normally this would only be done if you are changing batteries.
IMPORTANT NOTE! During a RESET TO FACTORY VALUES any
changes to the inverter/charger set up are also reset to the factory values if the
INVERT or CHARGE LEDs are on.
IMPORTANT NOTE! Function F11 (Battery #2 used for control) is NOT reset
during a RESET TO FACTORY VALUES.