Ge
urarHxir?
This
procedure
of
tuning
the
Linear
Amplifier
should
take
only
a
few
seconds
after
you
go
through
it
a
few
times.
Note
the
LOAD
control
position
so
it
can
be
preset
next
time
a
particular
band
is
used.
The
Linear
Amplifier
is
now
loaded
for
operation
at
maximum
input
power.
If
an
oscilloscope
is
being
used
for
monitoring,
a
display
similar
to
that
shown
in
Pictorial
22
should
be
obtained.
/
Page
47
Turn
the
exciter
to
standby
to
remove
drive
from
the
Linear
Amplifier.
The
Linear
Amplifier
is
now
ready
for
SSB
or
CW
transmission.
An
example
of
a
proper
oscilloscope
pattern
is
shown
in
Pictorial
23.
Note
that
there
are
sharp
distinct
peaks.
The
number
of
patterns
or
“christmas
trees”’
will
depend
on
the
individual
voice
and
the
scope
sweep
speed.
Set
the
scope
for
about
a
30
Hertz
sweep.
Oscilloscope
pattern
and
plate
meter
read-
ing
resulting
from
carrier
or
‘‘single
tone”
modulation.
The
meter
indicates
\
a
ea
PLATE
CURRENT
maximum
or
CW
power
input.
PICTORIAL
22
Oscilloscope
pattern
and
plate
meter
read-
ing
resulting
from
voice
modulation.
Notice
the
peaks
on
the
oscilloscope
pat-
tern.
They
are
sharp,
indicating
a
clean
signal,
and
they
will
attain
a
height
slightly
greater
than
the
‘“‘single
tone”’
pat-
tern
of
Pictorial
22,
indicating
maximum
PLATE
CURRENT
power
input.
NOTE:
Plate
current
peak
reading
is
approximately
1/2
or
less
of
maximum
‘‘single
tone’’
reading
due
to
meter
inertia
and
voice
characteristics.
PICTORIAL
23