MCBA PARAMETERS FOR THE SPECIALIST
Factory setting
Key Screen Description of parameters HM 35 TC HM 85 TC
STEP
Re-modulate the difference T1 - T2
STEP
Bus address
[-1 = disabled]
STEP
Temperature increase set point
for the production of hot water
STEP
00 : High temperature circuit - heating pump controlled by room
thermostat - hot water priority active
10 : Controlled circuit (outside sensor + AM3-11 module) - heating
pump controlled by room thermostat - hot water priority active
21 : Controlled circuit (outside sensor + AM3-11 module) - heating
pump runs continuously - night reduction possible - hot water
priority active
50 : Controlled circuit (outside sensor + AM3-11 module) - heating
pump controlled by room thermostat - hot water priority not
active
61 : Controlled circuit (outside sensor + AM3-11 module) - heating
pump runs continuously - night reduction possible - hot water
priority not active
STEP
Selection of the type of hot water production - That parameter is
fixed in a HeatMaster
®
TC and must not be changed
STEP
Manual fan speed
STEP
First position: PWM pump level during burning in, not used
Second position: PWM pump level during over-run time, not used
STEP
T set hold boiler warm
STEP
Maximum temperature for the 2nd heating circuit
STEP
Minimum temperature for the 2nd heating circuit
STEP
2nd circuit temperature hysteresis
STEP
First position: Special pump [0 = disabled]
Second position: Minimum disable cycle [0 = disabled]