13
OPERATION
Flame Characteristic
The flame pattern at the emitter screen should be visually
checked whenever heater is operated.
Normally the burner flame is blue, but little yellow flame is
acceptable.
If flames extend beyond surface of the emitter grid ,
or the phenomena of flame lift or light back, or black spot
is accumulating on the emitter grid or reflector, the heater
should be turned off immediately. The heater should not
be operated again until the unit is serviced and or repaired.
4. Push in gas control knob and turn counter clockwise to
"IGNITE" then to "PILOT" position, this will light the pilot.
If needed, keep depressing and turning control knob
counter clockwise until the pilot lights. (You will hear 1
clicking noise)
5. Once the pilot is lit, keep the control knob depressed for
approx. 30 seconds. Then release the control knob.
6. If pilot does not stay lit, repeat steps 4 and 5 after 5
minutes.
7. If pilot still does not stay lit, proceed as follows:
a) Push in gas control knob and turn counter clockwise
to the “PILOT” position.
b) Keep depressing the control knob, put a long stem
lighter into the ignition hole on the emitter screen
to light the pilot.
c) Repeat step 5.
8. Push in and turn control knob between “LOW” and
“HIGH” to get your desired warmth.
9. Close base assembly door.