5
PERFORMANCE
TABLE 01: Multipoint SS Performance; Heatup, Recovery & Heat Loss
MODEL HEAT UP TIME
(MINS)
RECOVERY
(MINS)
STANDING HEAT-
LOSS kWhr/24hr
50 litre 1.5kW 98 64 0.6
50 litre 3.0kW 49 32 0.6
80 litre 1.5kW 162 112 0.8
80 litre 3.0kW 81 56 0.8
100 litre 1.5kW 208 146 1.0
100 litre 3.0kW 104 73 1.0
Heat up times are based on heating from 20°C through 45°C tempera-
ture rise.
Recovery times are based on heating 70% of capacity through 45°C.
Standing heat losses are based on an ambient air temperature of 20°C
and a stored water temperature of 65°C.