16
ND 1202T TOOL-CHEK
Installation Instructions
Operating Instructions available at www.heidenhain.de
Connecting a USB cable
This product provides a USB connection for printer and data storage device
communication. For more information on USB communications, refer to the
ND 1202T TOOL-CHEK Operating Instructions.
To connect a USB printer or data storage device:
Verify that the power switch is in the off position.
Insert a printer USB (type A) cable or a USB data storage device into the products USB
port.
Connecting a foot switch or remote keypad
This product provides an RJ-45 foot switch/remote keypad connection for use with a
HEIDENHAIN foot switch (ID 681041-01) or HEIDENHAIN remote keypad (ID 681043-01).
To connect an RJ-45 foot switch/remote keypad cable:
Verify that the power switch is in the off position.
With the cable connector locking tab aligned with the connector, insert the cable
connector into the interface connector until the tab locks into place.
7. Operating elements
Front Front (cont)
A
LCD screen
H
Arrow cursor keys: Menu
navigation
B
Soft keys: Change to support
functions
I
Wide keys: Programmable for
frequently used functions
C
Feature selection keys: Initiate
measurement of features
J
Send key: Transmit measurement
data to PC, USB printer or USB drive
D
X axis key: Zero and freeze X axes
K
Mode keys: Select diameter/
radius, absolute/incremental, unit of
measure or help
E
Zero axis key: Initiates zeroing an
axis or axes
L
Numeric keypad: Enter numeric
data
F
Z axis key: Zero and freeze Z axes
M
Command keys: Control
measurement
G
Menu key: Displays user menus
N
LCD on/off key: Turn LCD on or off
or delete features from the feature
list.
11
USB connector
12
Foot switch/remote keypad
connector