EasyManua.ls Logo

HEIDENHAIN TNC 426 PB - Page 11

HEIDENHAIN TNC 426 PB
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
November 2001 2 9
List of error
messages
The error messages are listed in alphabetical order:
Error message Error
number
Cause of error Corrective action
3-D comp.: Plane
wrongly defined
314 n LN block: Calculation of the plane
direction resulted in an error.
n Have the components NX, NY and
NZ of the surface normals checked.
3DROT active: use
axis buttons
1178 n You have attempted to traverse the
reference marks with NC start,
although the function "Rotate
working plane" is active.
n Traverse reference marks using the
axis direction keys.
3DROT not
permitted
2526 n The tilted working plane function is
active during execution of a
digitizing cycle.
n Deactivate the tilted working plane
function and restart the program.
3DROT: No
description found
3063 n An incorrect path or file name of a
kinematic description is saved in
the assignment table for kinematic
descriptions.
n Correct the path or file name in the
assignment table. Copy the
kinematic description to the correct
directory.
3DROT: description
incomplete
3064 n Not all of the required machine
parameters are defined in a
kinematic description.
n Ensure that kinematic tables are
complete.
3DROT:No
assignment table
found
3062 n An incorrect path or file name for
the assignment table for kinematic
descriptions is saved in the
OEM.SYS under the code word
KINEMATIC=.
n Correct the path or file name in
OEM.SYS.
n Remove the code word
KINEMATIC= from OEM.SYS.
Machine parameters MP7500 and
following become active in the
currect machine parameter file.
8B00 Zn track axis
error
n Contamination of motor encoder
(Zn track).
n Motor encoder cable is defective.
n Drive control board defective.
n Inform your service agency.
n Exchange the motor.
n Check the motor encoder cable.
n Exchange drive control board.
8B30 Motor temp.
too high
n Measured motor temperature is too
high.
n No temperature sensor.
n Motor encoder cable is defective.
n Entry in motor table is incorrect.
n Incorrect or defective temperature
sensor was installed.
n Let the motor cool down.
n Inform your service agency.
n Check the motor encoder cable.
n Check the entry in the motor table.
8B50 Axis module
not ready
n Inverter is not ready for operation.
n No pulse release for the power
supply unit.
n Uz too high.
n Power-fail signal is active.
n On M controls: NE2 input active.
n On P controls: drive enable at X50
inactive.
n Motor control board defective.
n PWM cable defective.
n Noise signals.
n Inform your service agency.
n Check the control and cabling of
the pulse release.
n Check Uz.
n Check the emergency stop circuit.
n With non-energy recovery power
module: Braking resistor
connected?
n With energy-recovery power
module: Energy recovery active?
n Check the grounding and shielding
of the cable.
n Exchange the power module.
n on P controls: Exchange the
interface card.
n Exchange the motor drive control
board.

Other manuals for HEIDENHAIN TNC 426 PB