399
Operating and programming notes:
If you output the same file multiple times in the
program, then, within the target file, the control
adds the current output after the previously output
contents.
In the FN16 block, program the format file and the
log file with their respective file type extensions.
The file name extension of the log file
determines the file format of the output (e.g.,
TXT, .A, .XLS, .HTML).
In machine parameters fn16DefaultPath
(no. 102202) and fn16DefaultPathSim (no. 102203)
you can define a default path for outputting log files.
If you use FN16 the file must not be UTF8-encoded.
You receive a great deal of relevant and interesting
information for a log file by means of the function FN
18 (e.g., the number of the last touch probe cycle
used).
Further information: "FN 18: SYSREAD – Reading
system data", page 402