EasyManua.ls Logo

HEIDENHAIN TNC 640 - Page 756

HEIDENHAIN TNC 640
948 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual Operation and Setup | Using a 3-D touch probe
17
756
HEIDENHAIN | TNC 640 | Conversational Programming User's Manual | 10/2017
Writing measured values from the touch probe cycles
to a datum table
If you want to save measured values in the workpiece
coordinate system, use the ENTER IN DATUM TABLE
function. If you want to save measured values
in the basic coordinate system, use the
ENTRY IN PRESET TABLE function.
Further information: "Writing measured values from
the touch-probe cycles to the preset table", page 757
With the ENTER IN DATUM TABLE soft key, the control can write
the values measured during any touch-probe cycle to a datum
table:
Select any probe function
Enter the desired coordinates for the datum in the designated
input boxes (depends on the touch probe cycle being run)
Enter the datum number in the Number in table? input field
Press the ENTER IN DATUM TABLE soft key
The control saves the datum in the indicated datum table under
the entered number.

Table of Contents

Other manuals for HEIDENHAIN TNC 640

Related product manuals