Settings required in the HEIDENHAIN control:
After mounting the UM 11x
D, permanent changes to the machine parameter list and
possibly entries to the power module table of the HEIDENHAIN control are required.
1. Press the EMERGENCY STOP button!
2. Switch the machine power on.
3. Confirm messages of the electronic ID label that may be generated.
4. Do NOT confirm the "Power interrupted" message at the control!
5. Call the machine parameter list.
6. Deactivate the evaulation of the electronic ID labels for the HEIDENHAIN
power modules (for iTNC 530: MP 7690).
7. Call the power module table of the HEIDENHAIN control.
Select the HEIDENHAIN-UM11xDS service variant, and in the machine parameter "Type
of power module" (for iTNC 530: MP 2100.x) assign it to the axis or spindle where you
have replaced the HEIDENHAIN power module.
Defective unit
UM 112
UM 113
UM 114
UM 115
Exchange unit
UM 112
D
UM 113
D
UM 114
D
UM 115
D
Entry in machine parameter
HEIDENHAIN-UM112DS
HEIDENHAIN-UM113DS
HEIDENHAIN-UM114DS
HEIDENHAIN-UM115DS
Further information can be found in the Technical Manual of the respective
HEIDENHAIN control.
If you have any questions, contact the machine tool builder or HEIDENHAIN.