Caution:
1. Never fail to have an individual power circuit specifically for the air conditioner. As
for the method of wiring, refer to the circuit diagram posted on the inside of the
access door .
2. Comfirm that the cable thickness is as specified in the power source specification.
3. Check the wires and make sure that they are all tightly fastened after cable
connection.
4. Be sure to install an earth leakage circuit breaker in wet or moist areas.
Cable specifications
Note:
1.K* means the power supply of this model comes from indoor unit.
2. K** indicates indoor power supply unit model with power line and plug.
3. For 14K*~18K* models under Tropical(T3) Climate condition, the normal
cross-sectional area of Power cord and Power connecting cord is 2.5mm2×4.
Attention:
The plug must be accessible even after the installation of the appliance in case there
is a need to disconnect it. if not possible, connect applaince to a double-pole
switching device with contact separation of at least 3mm placed in an accesiblle
position even after installation.