3.4 Alarms:
Temperature guard has activated:
- The first (1) led of the column will be red and the green
On/Off led will flicker rapidly.
- Alarm delay is 10 seconds from detection of the fault.
Sensor cable or temperature sensor is short-circuited.
- The second (2) led in the column will be red and the green On/Off led will flicker rapidly.
- Alarm activates after a 10 second delay from the detection of the fault.
Sensor cable or temperature sensing device cut:
- The third (3) led in the column will be red and the green
On/Off led will flicker rapidly
- Alarm activates after a 240 second delay from the detection of the fault
Once the alarm has activated, the heater will switch off. Alarm will continue until the heater is
switched off using the On/Off button.
CONTACT A SERVICE REPRESENTATIVE WHEN NECESSARY. Repairs can only be
carried out by a competent electrical professional authorised to do so.