Optional equipment connections to the steam
generator terminal block.
*) 1.5 mm² external voltage supply 200V – 240V, fuse 10A
P = fragrance pump control output
F = Fan control output
There are 3 milled billets in the plastic end for strain relief nipples
for separate control cables.
1. Steam generator/Parallel coupling of steam generators, Max 5 steamers.
2. Thermostat
3. Control panel HNS T1
4. Remote start On / Off push button. Connecting instructions for the electronic push button on page 18.
Connecting the control cables
NOTE: The cable between the steam generator and the control panel must be screened, e.g. LiYCY 6 x 0.25mm².
Maximum cable length 50 m
Control panel T1 HNS T1 steamer's circuit board
connecting terminal markings connecting terminal markings
User and installation manual HNS-T1
10