Declaration of Performance EN
_____________________________________________________________________________
_________________________________________________________________________________________
In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid.
Heta A/S, Jupitervej 22, DK - 7620 Lemvig, Tlf.: +45 96630600, www.heta.dk
Page 1 of 1
Regulation No. 305/2011
DOP-Inspire 40 Indsats-2215-2016-EN
1. Unique identification code of product-type
Insert stoves
2. Product name
Inspire 40 Indsats
3. Intended use or uses of the construction
product, in accordance with the applicable
technical specification
Room heater burning solid fuel without hot water supply
4. Name and contact address of the
manufacturer
Heta A/S; Jupitervej 22
DK – 7620 Lemvig; heta@heta.dk
5. Where applicable, name and contact address
of authorized representative
@heta.dk
6. System of assessment and verification of
constancy of performance of the construction
product
System 3
7. Notified body relevant to the assessment and
verification of constancy of performance
Technologisk Institut DK 8000 Århus C
Notified body No. 1235
8. Declared Performance:
Harmonized technical specification
EN 13229:2001/A2:2004
Emission
CO: 0,05%
Nox: 111 mg/Nm³
Dust 8 mg/Nm³
Dust(NS3058/3059) 1,65 g/kg
OGS (CEN/TS 15883) 47 mgC/Nm³ ved 13% O2
9. Fire safety:
Reaction to fire
A1
Test of fire safety in connection with the burning of
wood.
Approved
Distance to combustible materials
Rear:
Sides distance to combustible materials
Furniture Distance:
Minimum distances i mm
- mm
150 mm
900 mm
10. safety:
Mechanical resistance (to carry a chimney / flue)
Not tested (NPD)
Electrical safety
NA
Surface temperature
Approved
Cleanability
No specification
11. Thermal output:
Nominal heat output
4 kW
Energy efficiency
84 %
Fluegas temperature at nominal heat output
T 216 °C
Water heating output
NA
Maximum water operating pressure
NA
The performance of the product identified in points1 and 2 is in conformity with the declared performance in point 8. This
declaration of performance is issued under the sole responsibility of the manufacturer.
Signed on behalf the manufacturer of:
____________________________________
Lemvig 18-08-2016. Lars Kirk HOD