A
B
D
C
E
D
150
150
300
E
H
I
G
F
108
50
50
108
25
Combustible material
2.8 Clearances for installation EN 13 240
SL 900 series
The dimensions are the
minimum dimensions,
unless otherwise stated.
Furnitures
- Non-flammable substrate
Oventype
Stove
Minimum
dimensions in
mm
Distance from oven to combustible material
Norwegian fire wall
Distance to firewall with 108 mm brick
A
Rear the sto-
ve insulated /
uninsulated
flue pipe
B
At the
side
C
Over
oven
D
To
furnitures
E
Corner
distance
F
Rear the
stove
uninsulated
flue pipe
G
At the side
uninsu-
lated flue
pipe
H
Length of
fire wall for-
ward in front
of oven
I
Length
of fire
wall next
to oven
Scan-Line
900
175/175 350 390 1000 100 50 150 500 100
Scan-Line 900
Side windows
125/150 400 390 900 200 50 200 400 200
Clearances
Norwegian fire wall
50 mm
insulated
-
108 mm brick -
Note your own number here _______________________