2. Application layer settings: It is mainly used to set the switching between people, static
and unmanned states. Enter an integer greater than 2 in the Static State window and click
Set. When the host computer continuously receives occ times greater than or equal to the
set value, the host computer displays that someone is still. For example, if it is set to 6, it
means that when the host computer needs to receive occ 6 times continuously, it will
display that someone is still.
3. Enter an integer > 1 in the switch unmanned window, and the host computer will enter the
system when it does not receive any data within the set time. into an unmanned state. The
window value unit is seconds. For example, if it is set to 30, it means that the radar output
will not be received within 30 seconds.
enter the unmanned state.