4
6. App Connection
Live view
HIKMICRO Academy
Set parameters
Upgrade device
Access albums
Capture snapshots and record videos
Android
iOS
7. Getting Started
Install Adapter
Install an adapter if you want to connect the device to a daylight scope.
Steps
1. Align the red dot of the adapter with the red dot of the
clip-on eyepiece, and insert the adapter as arrow 1 shows.
2. Rotate the fixing ring clockwise with the supplied wrench
(as arrow 2 shows) to secure the adapter.
Notes:
The adapter is not included in the package. Please
purchase it separately as needed.
The thread size is M52
*
0.75. Purchase the adapter
recommended by the manufacturer.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hikmicro Thunder TH35PC and is the answer not in the manual?

Hikmicro Thunder TH35PC Specifications

General IconGeneral
Resolution384 × 288
Pixel Pitch12 μm
Lens35 mm
Digital Zoom1x, 2x, 4x, 8x
Detection Range1800 m
ApertureF1.0
Image ModeWhite Hot, Black Hot, Red Hot, Fusion
Hot TrackYes
Protection LevelIP67
Thermal Sensitivity<35 mK
Frame Rate50 Hz
FocusManual
IP RatingIP67
NETD<35 mK
DisplayOLED, 1024x768
Battery TypeRechargeable Li-ion
Power SupplyDC 5V/2A
Dimensions187 x 62 x 59 mm
Operating Temperature-20°C to 55°C
Sensor TypeVOx Uncooled Focal Plane Arrays
Spectral Range8 μm to 14 μm
Storage Temperature-40°C to 70°C