2) Click Detecon Area.
3) Click on the live image to draw the boundaries of the detecon area, and right click to
complete drawing.
6.
Oponal: Set the minimum size and the maximum size for the target to improve detecon
accuracy. Only targets whose size are between the maximum size and the minimum size trigger
the
detecon.
1) Click Max. Size, and drag the mouse on live image. If you want to change the size, click the
buon and draw again.
2) Click Min. Size, and drag the mouse on the live image. If you want to change the size, click the
buon and draw again.
7.
Set
detecon parameters.
Sensivity The value of the sensivity denes the size of the object which can trigger the
alarm, when the sensivity is high, a very small object can trigger the alarm.
Threshold It stands for the me of the objects le in the area. Alarm is triggered aer the
object is le and stays in the area for the set me period.
Figure 8-9 Draw Area
8.
Click Save.
9.
Repeat above steps to set other regions.
10.
Set arming schedule. See
Set Arming Schedule .
11.
Set linkage method. See Linkage Method Sengs .